BlockRestrictionDebugOutput

Debug output object for displaying information regarding block-restriction of objects.

Overview

The BlockRestrictionDebugOutput object is, as the name suggests, designed to write out information regarding block-restriction of Moose objects for debugging purposes. Please refer to the Debug System for more information.

Input Parameters

  • nl_sysnl0The nonlinear system that we should output information for.

    Default:nl0

    C++ Type:NonlinearSystemName

    Unit:(no unit assumed)

    Controllable:No

    Description:The nonlinear system that we should output information for.

  • scopeallThe types of object to output block coverage for, if nothing is provided everything will be output.

    Default:all

    C++ Type:MultiMooseEnum

    Unit:(no unit assumed)

    Options:none, all, variables, kernels, auxvariables, auxkernels, materials, userobjects

    Controllable:No

    Description:The types of object to output block coverage for, if nothing is provided everything will be output.

  • use_displacedFalseEnable/disable the use of the displaced mesh for outputting

    Default:False

    C++ Type:bool

    Unit:(no unit assumed)

    Controllable:No

    Description:Enable/disable the use of the displaced mesh for outputting

Optional Parameters

  • additional_execute_onThe list of flag(s) indicating when this object should be executed. For a description of each flag, see https://mooseframework.inl.gov/source/interfaces/SetupInterface.html.

    C++ Type:ExecFlagEnum

    Unit:(no unit assumed)

    Options:NONE, INITIAL, LINEAR, NONLINEAR_CONVERGENCE, NONLINEAR, POSTCHECK, TIMESTEP_END, TIMESTEP_BEGIN, MULTIAPP_FIXED_POINT_END, MULTIAPP_FIXED_POINT_BEGIN, FINAL, FAILED, CUSTOM

    Controllable:No

    Description:The list of flag(s) indicating when this object should be executed. For a description of each flag, see https://mooseframework.inl.gov/source/interfaces/SetupInterface.html.

  • execute_onINITIALThe list of flag(s) indicating when this object should be executed. For a description of each flag, see https://mooseframework.inl.gov/source/interfaces/SetupInterface.html.

    Default:INITIAL

    C++ Type:ExecFlagEnum

    Unit:(no unit assumed)

    Options:NONE, INITIAL, LINEAR, NONLINEAR_CONVERGENCE, NONLINEAR, POSTCHECK, TIMESTEP_END, TIMESTEP_BEGIN, MULTIAPP_FIXED_POINT_END, MULTIAPP_FIXED_POINT_BEGIN, FINAL, FAILED, CUSTOM

    Controllable:No

    Description:The list of flag(s) indicating when this object should be executed. For a description of each flag, see https://mooseframework.inl.gov/source/interfaces/SetupInterface.html.

Execution Scheduling Parameters

  • control_tagsAdds user-defined labels for accessing object parameters via control logic.

    C++ Type:std::vector<std::string>

    Unit:(no unit assumed)

    Controllable:No

    Description:Adds user-defined labels for accessing object parameters via control logic.

  • enableTrueSet the enabled status of the MooseObject.

    Default:True

    C++ Type:bool

    Unit:(no unit assumed)

    Controllable:Yes

    Description:Set the enabled status of the MooseObject.

Advanced Parameters

  • end_stepTime step at which this output object stop operating

    C++ Type:int

    Unit:(no unit assumed)

    Controllable:No

    Description:Time step at which this output object stop operating

  • end_timeTime at which this output object stop operating

    C++ Type:double

    Unit:(no unit assumed)

    Controllable:No

    Description:Time at which this output object stop operating

  • min_simulation_time_interval0The minimum simulation time between output steps

    Default:0

    C++ Type:double

    Unit:(no unit assumed)

    Controllable:No

    Description:The minimum simulation time between output steps

  • simulation_time_interval1.79769e+308The target simulation time interval (in seconds) at which to output

    Default:1.79769e+308

    C++ Type:double

    Unit:(no unit assumed)

    Controllable:No

    Description:The target simulation time interval (in seconds) at which to output

  • start_stepTime step at which this output object begins to operate

    C++ Type:int

    Unit:(no unit assumed)

    Controllable:No

    Description:Time step at which this output object begins to operate

  • start_timeTime at which this output object begins to operate

    C++ Type:double

    Unit:(no unit assumed)

    Controllable:No

    Description:Time at which this output object begins to operate

  • sync_onlyFalseOnly export results at sync times

    Default:False

    C++ Type:bool

    Unit:(no unit assumed)

    Controllable:No

    Description:Only export results at sync times

  • sync_timesTimes at which the output and solution is forced to occur

    C++ Type:std::vector<double>

    Unit:(no unit assumed)

    Controllable:No

    Description:Times at which the output and solution is forced to occur

  • sync_times_objectTimes object providing the times at which the output and solution is forced to occur

    C++ Type:TimesName

    Unit:(no unit assumed)

    Controllable:No

    Description:Times object providing the times at which the output and solution is forced to occur

  • time_step_interval1The interval (number of time steps) at which output occurs. Unless explicitly set, the default value of this parameter is set to infinity if the wall_time_interval is explicitly set.

    Default:1

    C++ Type:unsigned int

    Unit:(no unit assumed)

    Controllable:No

    Description:The interval (number of time steps) at which output occurs. Unless explicitly set, the default value of this parameter is set to infinity if the wall_time_interval is explicitly set.

  • time_tolerance1e-14Time tolerance utilized checking start and end times

    Default:1e-14

    C++ Type:double

    Unit:(no unit assumed)

    Controllable:No

    Description:Time tolerance utilized checking start and end times

  • wall_time_interval1.79769e+308The target wall time interval (in seconds) at which to output

    Default:1.79769e+308

    C++ Type:double

    Unit:(no unit assumed)

    Controllable:No

    Description:The target wall time interval (in seconds) at which to output